|
Wizard:
- When BuildPlus cannot suggest a search path for a particular filetype,
the search path in Wizard is left blank instead of being filled in with
the default "C:\".
- The option to select DGN files to include in your project has been added.
- When the "Apply" button is pressed to change search directories to match
that of the main search path, the changes will not be applied to any filetype
that refers to the special "Decomposer" directories created in
the project directory for Composer projects.
- For the xdc files and colorder.dat and fontdef.dat files, the selection
has been automated more if only a single folder-single file is found for
the listed filetype.
BuildPlus:
- The Database-Graphics Associations have been improved to allow for mutliple
associations to be done for global graphics paths.
- When the user is running with the programs and files from the Overrides
directory, this setting will be indicated in the error files so that the
user knows that he is not building with the original build kit.
- DBSpec.vbs is now triggered to run for all builds.
- There is now a "Recent Projects" option under the "File" menu.
- A "Refresh" button has been added to the toolbar so that the menus, toolbar
button states and project settings can be updated with a push of a button.
- BuildPlus now ensures that the extracted databases all have unique names
to avoid conflicts with later processing in DBSpec.
- If Batch files are being included in a build and there are multiple UNT files
being associated to one B90 file, then BuildPlus will create a clone
of these files in the project directory in the "BATCH" subfolder.
- The build logs for the project have been moved to the "LOGS" folder located
in the project directory. The Management of Change files have also been
moved into their own "MOC" folder in the project directory.
- Ladder modules are now included in the "Duplicate Module Header" resolution
as it would wrong to build the same module for both Ladder and CAD.
- When starting a project from the "Build" button, BuildPlus will now check to
see if new SODG graphics folders have been added to the original search path
for graphics (specified in Wizard).
- BuldPlus now writes a summary of the types of filtered errors from the hyperlink
run and the number encountered of each type into the DBDOC.ERR, DBDOC_RESIDUAL.ERR
and DBDOC_SUMMARY.ERR files for ease of reference.
- BuildPlus will check to see if an Access database is created by Access 97 before
carrying out any database processing as our database utilities do not handle Access
2000.
- The detection of a different version of MCRSize.dbf will now trigger a full decomposer
run for all Composer projects.
- The "Decomposer Directory Source" window is now an independent window that can be
kept open while you perform other operations in BuildPlus.
Hyperlink:
- Code has been implemented in order to facilitate the launching of the Graphics
Cross-References in its own separate floating window.
- Titles are now limited to 128 characters in order for Mediaview Compiler to accept
them.
- Sizing of data for continuous live loop monitoring on Conductor NT graphics has been
corrected so that it is consistent.
- Hyperlink will check for incorrectly set spec 20 on FC 177 as this spec means there
will not be an alarm when there possibly should be.
- Overlapping External Block definitions are now handled.
- Hyperlink generates three unused tag reports - Unused_tags.txt, Unused-alarm_tags.txt
and Unused-unconfigured_tags.txt.
- Various fixes have gone in to handle FC 156 and FC 136.
- Tags that are not on their primary display are now being reported.
- Hyperlink will report tagnames which contain a '/' in them if they are PCView as such
tags are illegal in PCView.
- Support has been added to implement the "View As Dynamic Bar" feature in Hyperview.
(See Hyperview #4)
- New support has been added to handle the processing of DGN files.
- Support for AutoCAD 2004 has been added.
- A new directive to strip off prefixes on tags in Wonderware databases has been added.
- The orientation of vertical text on Conductor NT graphics has been fixed.
- Trend configuration and historical database tags are now getting linked to correctly
in the xdcdump file.
- There are improvements in drawing Conductor NT graphics.
- Additional support for new tagatoms has been added.
- The number of rung blocks in ladder files reported in our summary files
has been corrected.
- Conductor NT graphics can now be called up by number.
Hyperview:
- The Graphics Cross-Reference are now presented in its own separate floating window.
- Overlapping External Block definitions are now handled.
- You can now search for tags in the "Define Live Loop Annotation" dialog with
psuedotags, scanned tags or other aliases.
- Display any data as a dynamic bar graph whether it is binary or analog.
- The graphing of Function Code 1 has been corrected where the last point was getting
missed.
- Live loop monitoring boxes on ladder files have been fixed so that they are the
correct size.
- The new command line switch MonitorOff allows the user to specify that live loop
monitoring be turned off after a given interval (in minutes).
- The "Manage Bookmarks" dialog is now sizable and its settings retained between runs
of Hyperview.
- Support for DGN files has been added (in conjunction with Hyperlink).
- Bitmaps on Conductor NT graphics now get printed when the graphic is printed.
Decomposer:
- Work has been put in in order to enable the faciliation of the floating cross-
reference in Hyperview. (See Hyperview #1)
- Decomposer translates the EBY name into the appropriate user name or CAD name for
easier reference by the user.
- A problem where Decomposer "got lost parsing" a client CLD file has been resolved.
- Corrected macro size for FC 51.
- The handling of FC 21, 22 and 23 spec position has been corrected.
- SYMEMPTY.DBF has been modified to handle up to 64 character long names.
Database Utilities:
- Our visual basic scripts have been modified to set the locale to "en-us" in order
for processing to occur correctly when operating on systems with differently set
locales.
- Tags that are specified Module 0,00,00 Block 0000 are not included in our TD_NOLIST
when it is extracted with our DBSynth program (for FoxPro databases).
- New database templates have been included for our TTX2DBF processing (for TTG,TTR
databases).
CIULink:
- Save the users view preference to the registry so that CIULink opens up to that
view on start-up.
- There is a new option under "Tag Monitoring" that allows you to specify the number
of significant digits that get displayed in Export view.
- A fix has been added to correct the display when monitoring in CIULink and Excel at
the same time.
- The interface to set the frequency at which data will be requested has been improved.
CIUMon:
- A new option - "Modify Service Properties" - has been added for the CIUMon service
handling.
- There is now an option of adding on a watcher service to your regular CIUMon service.
- CIUMon gives the user the option of keeping track of user statistics.
- There is a new option to display the IP Address of the requestor; this will be appended
to the end of each request.
- Contextual help has been added to all dialog boxes.
- A fix has been added to correct the problem where some clients would see the VSP
splashscreen appear continuously when CIUMon was started up.
- A tool has been created, VSPCleanup.exe, that will wholesale remove all traces of
virtual serial ports on a computer when there appears to be a problem removing them
through the regular VirtualPortSetup application.
- General clean-up of memory leaks.
DataFiles:
- Errfilter.cfg has been modified to handle new messages generated by Hyperlink.
- Filetypes.txt has been changed to accomodate new features.
- Param.txt has been modified to accomodate new features.
- Output.txt has been modified to correct a problem on FC 136 (Output N+3 was specified
as binary, not real).
View Details
Release Notes Index | GMCL DBDOC Home
|
|